2180

BUC-Ku02-11.3 v2.0

Short description

BUC-Ku02-11.3 is block up-converter with fixed output power P1dB 2 W (ALC power: 200 mW) and LO of 11.3 GHz.

Our BUC operates with up to 25 carriers and has built-in reference of 10 MHz;

and ALC with 25 dB range;

IP Ctrl (by order)

+ LED status indication at the rear side.

- +
  • Description
  • Downloads

2 W Ku-band block up-converter with LO of 11.3 GHz BUC-Ku02-11.3-v2.0 is designed for MVDS TV broadcasting systems application in accordance with DVB-S/S2 or DVB-C standards (use “Customized” button to choose needed parameters) and operates with up to 25 carriers. BUC-Ku02-11.3-v2.0 has output flange of PBR120 type and can be used with regular radio-relay link (directional) or broadcast (sector and OMNI) antennas. BUC-Ku02-11.3-v2.0 supports all modulation types up to 32APSK and 256QAM (you may choose the modulation type while filling the “customized equipment” form). BUC-Ku02-11.3-v2.0 has the best linearity parameters to ensure the stability of the output frequency and low IMD3 level (these parameters are very important for high quality modulation, therefore the local oscillator of BUC-Ku02-11.3-v2.0 is locked by PLL with internal frequency reference). BUC-Ku02-11.3-v2.0 provides 12.25 – 13.25 GHz output frequency range (bandwidth in Ku-band) for 950-1950 MHz input frequency range (bandwidth in L-band).

LO: 11.3 GHz    IN: 950 – 1950 MHz    OUT: 12.25 – 13.25 GHz

 

KEY FEATURES:

  • Output flange: PBR120
  • Output power (P1dB, min): 2 W
  • Output frequency range: 12.25 – 13.25 GHz
  • Input frequency range: 950 – 1950 MHz
  • Gain (min): 53 dB
  • Highly stable internal frequency reference
  • LO is locked by PLL with internal frequency reference
  • IMD3 level at ALC output power (the lowest value): -37 dBc max
  • Operates with up to 25 carriers
  • Supported modulation types: up to 32APSK and 256QAM
Input parameters:
Input frequency range 950 – 1950 MHz
Input impedance 50 Ohm
Input level, max -12 dBm 
Input VSWR, max 1.5
Input interface N-type Female 
ALC range, min 25 dB 
ALC threshold level -30 dBm
Local oscilator:
LO frequency  11300 MHz 
LO phase noise:
@1 kHz -80 dBc/Hz 
@10 kHz -85 dBc/Hz 
@100 kHz -100 dBc/Hz
LO instability ± 2 ppm
Output parameters:
Output frequency range 12250 – 13250 MHz
Output power @P1dB 2 W
ALC output power 200 mW
Gain, min 53 dB
IMD3 level at ALC output power, max -37 dBc
Output interface Waveguide WR75, Flange PBR120
Output VSWR, max 2
Frequency response:
Flatness over Full Band ± 1.5 dB
Spurious:
In-band @P1dB, max -55 dBc
Out-Band, max -30 dBm
LO leakage at ALC output power, max -40 dBm
Image rejection, min 60 dB
Power supply:
Input voltage 18 – 30 VDC, nominal 24 VDC
Power consumption, max 15 W
Environmental:
Operating temperature -40℃ to +50℃ (-40℉ to +122℉) 
Storage temperature -60℃ to +80℃ (-76℉ to +176℉)
Operating humidity 100%, non‐condensing
Mechanical:
Dimensions (W x H x D) 104x89x157 mm
Weight 1.15kg

Taking into consideration that we (UMT LLC) are developer and system integrator, also do not stop on our technical growth and improvement, know that view of all our devices and equipment including their technical parameters may be different from pictures presented on website and parameters listed on each device webpage. 
Note! All details customer has to confirm in advance during ordering and before payment. Those parameters that were not specified and / or were not agreed while ordering will be implemented as basic at the discretion of the manufacturer. Each our customer has 1.5 year warranty and 7 year aftersales support for whole range of our products. 